Helium log

FIBA6449033

DRT-01

March 16, 2026 · 16:00

Top OffCaution

Manual inputs

Site name
DRT-01
Trailer water volume (cu ft)
478.87
Barometric pressure
30.3
Beginning tank temp (°F)
41
Beginning trailer pressure (psig)
1,290
Ending tank temp (°F)
41
Ending trailer pressure (psig)
1,240

Calculated fields

Beginning capacity (cu ft)
43,042
Ending capacity (cu ft)
41,460
Volume delivered (cu ft)
1,582
Standard lbs lift added
102
Compressibility (begin)
1.04573449
Temp expansion (begin)
0.9994519
Pressure expansion (begin)
1.0009546
Volume correction (begin)
89.88253262
Compressibility (end)
1.04399596
Temp expansion (end)
0.9994519
Pressure expansion (end)
1.0009176
Volume correction (end)
86.57918813
Beginning capacity (cu m)
1,218.813711
Ending capacity (cu m)
1,174.01646
Volume delivered (cu m)
44.797251

Audit

Record ID
deea544d-1743-498d-aa31-b79c44201851
Created
2026-04-09 14:17:43
Updated
2026-04-09 14:17:43