Helium log

HPCA-0219

BMA

January 16, 2026 · 17:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
39.75
Barometric pressure
29.8
Beginning tank temp (°F)
110
Beginning trailer pressure (psig)
2,700
Ending tank temp (°F)
100
Ending trailer pressure (psig)
950

Calculated fields

Beginning capacity (cu ft)
6,329
Ending capacity (cu ft)
2,401
Volume delivered (cu ft)
3,928
Standard lbs lift added
254
Compressibility (begin)
1.08187518
Temp expansion (begin)
1.000756
Pressure expansion (begin)
1.001998
Volume correction (begin)
159.22344253
Compressibility (end)
1.03004062
Temp expansion (end)
1.000567
Pressure expansion (end)
1.000703
Volume correction (end)
60.39895597
Beginning capacity (cu m)
179.217322
Ending capacity (cu m)
67.988749
Volume delivered (cu m)
111.228573

Audit

Record ID
daadd319-4086-4205-baeb-cb1e368fe721
Created
2026-04-09 14:35:26
Updated
2026-04-09 14:35:26