Helium log

HPCA-0346

BMA

March 13, 2026 · 16:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
44.14
Barometric pressure
29.88
Beginning tank temp (°F)
101
Beginning trailer pressure (psig)
4,600
Ending tank temp (°F)
81
Ending trailer pressure (psig)
3,650

Calculated fields

Beginning capacity (cu ft)
11,537
Ending capacity (cu ft)
9,690
Volume delivered (cu ft)
1,847
Standard lbs lift added
119
Compressibility (begin)
1.13969687
Temp expansion (begin)
1.0005859
Pressure expansion (begin)
1.003404
Volume correction (begin)
261.3819005
Compressibility (end)
1.11630137
Temp expansion (end)
1.0002079
Pressure expansion (end)
1.002701
Volume correction (end)
219.52517836
Beginning capacity (cu m)
326.691459
Ending capacity (cu m)
274.390243
Volume delivered (cu m)
52.301216

Audit

Record ID
cf208d35-f942-4cdf-bce2-aeff3d2a9010
Created
2026-04-09 14:45:31
Updated
2026-04-09 14:45:31