Helium log
FIBA6302002
BBT-01
March 7, 2026 · 17:00
Top OffCaution
Helium trailer log — FIBA6302002
BBT-01 · 2026-03-07 17:00 · Top Off · ORANGE
Manual inputs
- Site name
- BBT-01
- Trailer water volume (cu ft)
- 506.41
- Barometric pressure
- 30.02
- Beginning tank temp (°F)
- 77.2
- Beginning trailer pressure (psig)
- 1,500
- Ending tank temp (°F)
- 73.5
- Ending trailer pressure (psig)
- 1,410
Calculated fields
- Beginning capacity (cu ft)
- 49,155
- Ending capacity (cu ft)
- 46,662
- Volume delivered (cu ft)
- 2,493
- Standard lbs lift added
- 161
- Compressibility (begin)
- 1.04917039
- Temp expansion (begin)
- 1.00013608
- Pressure expansion (begin)
- 1.00111
- Volume correction (begin)
- 97.06572345
- Compressibility (end)
- 1.04662707
- Temp expansion (end)
- 1.00006615
- Pressure expansion (end)
- 1.0010434
- Volume correction (end)
- 92.14286965
- Beginning capacity (cu m)
- 1,391.914594
- Ending capacity (cu m)
- 1,321.320696
- Volume delivered (cu m)
- 70.593899
Audit
- Record ID
- cef6320c-fabd-4dee-b3c1-b8a6c2c5e008
- Created
- 2026-04-09 14:23:17
- Updated
- 2026-04-09 14:24:10