January 2, 2026 · 17:00
Top OffAdequate
Helium trailer log — FIBA6302002
BBT-01 · 2026-01-02 17:00 · Top Off · GREEN
Manual inputs
- Site name
- BBT-01
- Trailer water volume (cu ft)
- 506.41
- Barometric pressure
- 30
- Beginning tank temp (°F)
- 85
- Beginning trailer pressure (psig)
- 1,700
- Ending tank temp (°F)
- 83
- Ending trailer pressure (psig)
- 1,600
Calculated fields
- Beginning capacity (cu ft)
- 54,576
- Ending capacity (cu ft)
- 51,721
- Volume delivered (cu ft)
- 2,855
- Standard lbs lift added
- 184
- Compressibility (begin)
- 1.05471708
- Temp expansion (begin)
- 1.0002835
- Pressure expansion (begin)
- 1.001258
- Volume correction (begin)
- 107.7698752
- Compressibility (end)
- 1.05176954
- Temp expansion (end)
- 1.0002457
- Pressure expansion (end)
- 1.001184
- Volume correction (end)
- 102.1330123
- Beginning capacity (cu m)
- 1,545.42022
- Ending capacity (cu m)
- 1,464.575623
- Volume delivered (cu m)
- 80.844597
Audit
- Record ID
- b5b25c7e-7e79-4942-959e-b78a05691a7d
- Created
- 2026-04-09 14:21:33
- Updated
- 2026-04-09 14:21:33