Helium log

HPCA-0189

BMA

April 24, 2026 · 16:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
39.75
Barometric pressure
29.7
Beginning tank temp (°F)
101
Beginning trailer pressure (psig)
4,225
Ending tank temp (°F)
108
Ending trailer pressure (psig)
4,175

Calculated fields

Beginning capacity (cu ft)
9,636
Ending capacity (cu ft)
9,433
Volume delivered (cu ft)
203
Standard lbs lift added
13
Compressibility (begin)
1.12869463
Temp expansion (begin)
1.0005859
Pressure expansion (begin)
1.0031265
Volume correction (begin)
242.41008212
Compressibility (end)
1.12547987
Temp expansion (end)
1.0007182
Pressure expansion (end)
1.0030895
Volume correction (end)
237.29568639
Beginning capacity (cu m)
272.861134
Ending capacity (cu m)
267.112814
Volume delivered (cu m)
5.74832

Audit

Record ID
abb3d069-96fa-4b17-bfba-ae479dccc945
Created
2026-04-24 13:55:55
Updated
2026-04-24 13:55:55