Helium log

HPCA-0346

BMA

March 27, 2026 · 16:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
44.14
Barometric pressure
29.97
Beginning tank temp (°F)
98
Beginning trailer pressure (psig)
3,800
Ending tank temp (°F)
88
Ending trailer pressure (psig)
2,300

Calculated fields

Beginning capacity (cu ft)
9,779
Ending capacity (cu ft)
6,280
Volume delivered (cu ft)
3,499
Standard lbs lift added
226
Compressibility (begin)
1.11685078
Temp expansion (begin)
1.0005292
Pressure expansion (begin)
1.002812
Volume correction (begin)
221.53395664
Compressibility (end)
1.07311227
Temp expansion (end)
1.0003402
Pressure expansion (end)
1.001702
Volume correction (end)
142.2726381
Beginning capacity (cu m)
276.910443
Ending capacity (cu m)
177.829797
Volume delivered (cu m)
99.080646

Audit

Record ID
a688ef2e-595f-40f8-9342-17ec9f5a9f86
Created
2026-04-09 14:46:14
Updated