Helium log
HPCA-0362
BMA
December 18, 2025 · 17:00
Top OffCritical
Helium trailer log — HPCA-0362
BMA · 2025-12-18 17:00 · Top Off · RED
Manual inputs
- Site name
- BMA
- Trailer water volume (cu ft)
- 44.14
- Barometric pressure
- 29.87
- Beginning tank temp (°F)
- 120
- Beginning trailer pressure (psig)
- 2,150
- Ending tank temp (°F)
- 80
- Ending trailer pressure (psig)
- 600
Calculated fields
- Beginning capacity (cu ft)
- 5,597
- Ending capacity (cu ft)
- 1,778
- Volume delivered (cu ft)
- 3,819
- Standard lbs lift added
- 247
- Compressibility (begin)
- 1.06431876
- Temp expansion (begin)
- 1.000945
- Pressure expansion (begin)
- 1.001591
- Volume correction (begin)
- 126.80627185
- Compressibility (end)
- 1.01996273
- Temp expansion (end)
- 1.000189
- Pressure expansion (end)
- 1.000444
- Volume correction (end)
- 40.28150023
- Beginning capacity (cu m)
- 158.48939
- Ending capacity (cu m)
- 50.347353
- Volume delivered (cu m)
- 108.142037
Audit
- Record ID
- a5cac7ab-3f2e-4e6f-9f9a-734dcdfa1036
- Created
- 2026-04-09 14:33:25
- Updated
- 2026-04-09 14:36:33