Helium log

HPCA-0346

BMA

April 23, 2026 · 16:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
44.14
Barometric pressure
29.81
Beginning tank temp (°F)
90
Beginning trailer pressure (psig)
1,000
Ending tank temp (°F)
80
Ending trailer pressure (psig)
50

Calculated fields

Beginning capacity (cu ft)
2,849
Ending capacity (cu ft)
190
Volume delivered (cu ft)
2,659
Standard lbs lift added
172
Compressibility (begin)
1.03221262
Temp expansion (begin)
1.000378
Pressure expansion (begin)
1.00074
Volume correction (begin)
64.53978621
Compressibility (end)
1.00210724
Temp expansion (end)
1.000189
Pressure expansion (end)
1.000037
Volume correction (end)
4.30989375
Beginning capacity (cu m)
80.674696
Ending capacity (cu m)
5.380201
Volume delivered (cu m)
75.294495

Audit

Record ID
8dd7fbca-b1a0-41fc-ae9d-34829dfd8a39
Created
2026-04-24 13:54:23
Updated
2026-04-24 14:07:23