Helium log

HPCA-0189

BMA

April 23, 2026 · 16:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
39.75
Barometric pressure
29.81
Beginning tank temp (°F)
98
Beginning trailer pressure (psig)
4,600
Ending tank temp (°F)
80
Ending trailer pressure (psig)
4,100

Calculated fields

Beginning capacity (cu ft)
10,437
Ending capacity (cu ft)
9,696
Volume delivered (cu ft)
741
Standard lbs lift added
48
Compressibility (begin)
1.14053524
Temp expansion (begin)
1.0005292
Pressure expansion (begin)
1.003404
Volume correction (begin)
262.57800774
Compressibility (end)
1.1304389
Temp expansion (end)
1.000189
Pressure expansion (end)
1.003034
Volume correction (end)
243.92433725
Beginning capacity (cu m)
295.542928
Ending capacity (cu m)
274.560145
Volume delivered (cu m)
20.982783

Audit

Record ID
7def0011-432a-4bd8-9151-db7ce1d1c1ae
Created
2026-04-24 13:54:59
Updated
2026-04-24 14:06:52