Helium log
HPCA-0286
BMA
February 27, 2026 · 17:00
Top OffCritical
Helium trailer log — HPCA-0286
BMA · 2026-02-27 17:00 · Top Off · RED
Manual inputs
- Site name
- BMA
- Trailer water volume (cu ft)
- 44.14
- Barometric pressure
- 29.87
- Beginning tank temp (°F)
- 99
- Beginning trailer pressure (psig)
- 2,600
- Ending tank temp (°F)
- 85
- Ending trailer pressure (psig)
- 800
Calculated fields
- Beginning capacity (cu ft)
- 6,909
- Ending capacity (cu ft)
- 2,321
- Volume delivered (cu ft)
- 4,588
- Standard lbs lift added
- 296
- Compressibility (begin)
- 1.0806279
- Temp expansion (begin)
- 1.0005481
- Pressure expansion (begin)
- 1.001924
- Volume correction (begin)
- 156.51610438
- Compressibility (end)
- 1.02615866
- Temp expansion (end)
- 1.0002835
- Pressure expansion (end)
- 1.000592
- Volume correction (end)
- 52.59144345
- Beginning capacity (cu m)
- 195.641093
- Ending capacity (cu m)
- 65.723401
- Volume delivered (cu m)
- 129.917692
Audit
- Record ID
- 6a734cd8-aeed-4972-b349-8644c604ff36
- Created
- 2026-04-09 14:43:44
- Updated
- 2026-04-09 14:43:44