Helium log

HPCA-0219

BMA

January 2, 2026 · 17:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
39.75
Barometric pressure
29.87
Beginning tank temp (°F)
103
Beginning trailer pressure (psig)
3,800
Ending tank temp (°F)
100
Ending trailer pressure (psig)
2,700

Calculated fields

Beginning capacity (cu ft)
8,737
Ending capacity (cu ft)
6,432
Volume delivered (cu ft)
2,305
Standard lbs lift added
149
Compressibility (begin)
1.11569739
Temp expansion (begin)
1.0006237
Pressure expansion (begin)
1.002812
Volume correction (begin)
219.81027319
Compressibility (end)
1.08348679
Temp expansion (end)
1.000567
Pressure expansion (end)
1.001998
Volume correction (end)
161.79881611
Beginning capacity (cu m)
247.404289
Ending capacity (cu m)
182.133957
Volume delivered (cu m)
65.270331

Audit

Record ID
53362e86-78e5-4fc4-92df-69cabdc00a0d
Created
2026-04-09 14:34:44
Updated
2026-04-09 14:34:44