Helium log
HPCA-0362
BMA
December 4, 2025 · 17:00
Top OffCritical
Helium trailer log — HPCA-0362
BMA · 2025-12-04 17:00 · Top Off · RED
Manual inputs
- Site name
- BMA
- Trailer water volume (cu ft)
- 44.14
- Barometric pressure
- 29.91
- Beginning tank temp (°F)
- 110
- Beginning trailer pressure (psig)
- 3,300
- Ending tank temp (°F)
- 98
- Ending trailer pressure (psig)
- 2,250
Calculated fields
- Beginning capacity (cu ft)
- 8,448
- Ending capacity (cu ft)
- 6,052
- Volume delivered (cu ft)
- 2,396
- Standard lbs lift added
- 155
- Compressibility (begin)
- 1.09953224
- Temp expansion (begin)
- 1.000756
- Pressure expansion (begin)
- 1.002442
- Volume correction (begin)
- 191.38147881
- Compressibility (end)
- 1.07014922
- Temp expansion (end)
- 1.0005292
- Pressure expansion (end)
- 1.001665
- Volume correction (end)
- 137.10089285
- Beginning capacity (cu m)
- 239.22072
- Ending capacity (cu m)
- 171.373556
- Volume delivered (cu m)
- 67.847164
Audit
- Record ID
- 474e576c-c640-4593-ae69-c39e4e4b57e9
- Created
- 2026-04-09 14:32:54
- Updated
- 2026-04-09 14:32:54