Helium log

HPCA-093

BMA

December 4, 2025 · 17:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
39.75
Barometric pressure
29.91
Beginning tank temp (°F)
110
Beginning trailer pressure (psig)
950
Ending tank temp (°F)
98
Ending trailer pressure (psig)
50

Calculated fields

Beginning capacity (cu ft)
2,361
Ending capacity (cu ft)
166
Volume delivered (cu ft)
2,195
Standard lbs lift added
142
Compressibility (begin)
1.02946995
Temp expansion (begin)
1.000756
Pressure expansion (begin)
1.000703
Volume correction (begin)
59.38614575
Compressibility (end)
1.00203535
Temp expansion (end)
1.0005292
Pressure expansion (end)
1.000037
Volume correction (end)
4.17567096
Beginning capacity (cu m)
66.856075
Ending capacity (cu m)
4.700597
Volume delivered (cu m)
62.155478

Audit

Record ID
44cdc81e-2424-4ad4-8c99-9c418908d4a4
Created
2026-04-09 14:32:07
Updated