Helium log

HPCA-0362

BMA

January 2, 2026 · 17:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
44.14
Barometric pressure
29.87
Beginning tank temp (°F)
103
Beginning trailer pressure (psig)
600
Ending tank temp (°F)
100
Ending trailer pressure (psig)
1

Calculated fields

Beginning capacity (cu ft)
1,708
Ending capacity (cu ft)
45
Volume delivered (cu ft)
1,663
Standard lbs lift added
107
Compressibility (begin)
1.01907878
Temp expansion (begin)
1.0006237
Pressure expansion (begin)
1.000444
Volume correction (begin)
38.68524979
Compressibility (end)
1.00049131
Temp expansion (end)
1.000567
Pressure expansion (end)
1.00000074
Volume correction (end)
1.00946754
Beginning capacity (cu m)
48.365174
Ending capacity (cu m)
1.274258
Volume delivered (cu m)
47.090916

Audit

Record ID
384ac5d5-d7da-41cf-b901-00d7244013f3
Created
2026-04-09 14:34:12
Updated