Helium log

HPCA-0346

BMA

April 10, 2026 · 16:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
44.14
Barometric pressure
29.96
Beginning tank temp (°F)
90
Beginning trailer pressure (psig)
2,350
Ending tank temp (°F)
91
Ending trailer pressure (psig)
1,000

Calculated fields

Beginning capacity (cu ft)
6,385
Ending capacity (cu ft)
2,844
Volume delivered (cu ft)
3,541
Standard lbs lift added
229
Compressibility (begin)
1.07436669
Temp expansion (begin)
1.000378
Pressure expansion (begin)
1.001739
Volume correction (begin)
144.65842727
Compressibility (end)
1.03215126
Temp expansion (end)
1.0003969
Pressure expansion (end)
1.00074
Volume correction (end)
64.43230923
Beginning capacity (cu m)
180.803065
Ending capacity (cu m)
80.533112
Volume delivered (cu m)
100.269954