Helium log
WCG000531-6
Tower 22
April 13, 2026 · 16:00
Top OffAdequate
Helium trailer log — WCG000531-6
Tower 22 · 2026-04-13 16:00 · Top Off · GREEN
Manual inputs
- Site name
- Tower 22
- Trailer water volume (cu ft)
- 479.1
- Barometric pressure
- 30.01
- Beginning tank temp (°F)
- 40
- Beginning trailer pressure (psig)
- 2,200
- Ending tank temp (°F)
- 37
- Ending trailer pressure (psig)
- 2,040
Calculated fields
- Beginning capacity (cu ft)
- 71,133
- Ending capacity (cu ft)
- 66,694
- Volume delivered (cu ft)
- 4,439
- Standard lbs lift added
- 287
- Compressibility (begin)
- 1.07734233
- Temp expansion (begin)
- 0.999433
- Pressure expansion (begin)
- 1.001628
- Volume correction (begin)
- 148.472696
- Compressibility (end)
- 1.07229051
- Temp expansion (end)
- 0.9993763
- Pressure expansion (end)
- 1.0015096
- Volume correction (end)
- 139.20708628
- Beginning capacity (cu m)
- 2,014.262249
- Ending capacity (cu m)
- 1,888.563767
- Volume delivered (cu m)
- 125.698482
Audit
- Record ID
- 2a701274-b8f0-49da-92f8-51d6ba21c6a6
- Created
- 2026-04-18 14:46:18
- Updated
- 2026-04-18 14:46:18