Helium log

HPCA-0219

BMA

January 31, 2026 · 17:00

Top OffCritical

Manual inputs

Site name
BMA
Trailer water volume (cu ft)
39.75
Barometric pressure
29.87
Beginning tank temp (°F)
107.1
Beginning trailer pressure (psig)
925
Ending tank temp (°F)
97.9
Ending trailer pressure (psig)
1

Calculated fields

Beginning capacity (cu ft)
2,312
Ending capacity (cu ft)
40
Volume delivered (cu ft)
2,272
Standard lbs lift added
147
Compressibility (begin)
1.02887023
Temp expansion (begin)
1.00070119
Pressure expansion (begin)
1.0006845
Volume correction (begin)
58.17155126
Compressibility (end)
1.00049331
Temp expansion (end)
1.00052731
Pressure expansion (end)
1.00000074
Volume correction (end)
1.01322732
Beginning capacity (cu m)
65.468549
Ending capacity (cu m)
1.132674
Volume delivered (cu m)
64.335875

Audit

Record ID
13cd31f5-e0e7-49cf-be3c-55351a5233e0
Created
2026-04-09 14:36:14
Updated
2026-04-09 14:36:14